Document Page: First | Prev | Next | All | Image | This Release | Search
File: 061496_jun_decls5_0005.txt
Subject: MAINTENANCE ADVISORY ON SAFETY OF USE MESSAGES
Box ID: BX001440
Unit: 24TH ID
Parent Organization: XVIII CORPS
Folder Title: 24 IN DIV PROCEDURES
Folder Seq #: 171
Document Number: 7
Document Date:
Scan Date: 04-JUN-1996
R 30150OZ NOV 90
FM CDR AMCCOM ROCK ISLAND IL//AMSMC-QAS//
TO AIG 9874
AIG 7481
SUBJECT: AMMUNITION INFORMATION NOTICE (AIN) 13-91;
PRECAUTION TO PREVENT BUILDUP OF PROPELLANT RETAINING CLIPS
DURING FIRING OF 4.2 INCH MORTARS.
A. TM 9-1015-215-10, OPERATOR'S MANUAL FOR 4.2 INCH MORTAR,.
M30.
1. AIN 12-91 WAS XMITTED ON 30143OZ NOV-90.
2. THIS SUPERSEDES AIN 21-90.
3. REQUEST QASAS ORG ASSURE THIS INFORMATION IS PASSED TO
ALL POTENTIAL USERS WITHIN THEIR AREA OF SUPPORT.
4. PROPELLANT RETAINING CLIPS ARE KNOWN TO FALL OFF DURING
FIRING OF 4.2 INCH MORTAR CTGS. PRECAUTIONS ARE TO BE TAKEN
DURING FIRING TO PREVENT BUILDUP OF CLIPS IN BASE OF TUBE AND
TO REDUCE POTENTIAL FOR MISFIRES. FOL CAUTIONS WILL BE ADDED
TO REF AND ARE TO BE IMPLEMENTED IMMEDIATELY:
A. CAUTION: BOTTOM OF TUBE IS TO BE CHECKED (VISUALLY)
APPROX EVERY 40 ROUNDS. IF MORE THAN FIVE
PROPELLANT HOLDING CLIP WIRES ARE LYING IN
THE TUBE, THEY SHOULD BE REMOVED BY DUMPING
TUBE.
B. CAUTION: TO PREVENT A POSSIBLE MISFIRE, ASSURE PRIOR
TO FIRING, THAT PROPELLANT HOLDING CLIPS
ARE SEATED IN GROOVES PROVIDED ON THE
IGNITION CTG CONTAINER OR EXTENSION. SEE
PAGES 4-46 AND 4-47 FOR ILLUSTRATION.
5. TESTING HAS INDICATED THAT SOME PROPELLANT HOLDING CLIP
WIRES WILL FALL OFF EVEN IF PROPERLY SEATED IN THE GROOVES
PROVIDED ON THE CTG CONTAINER AND EXTENSION. TESTING
INDICATED THAT BUILDUP SUFFICIENT TO CAUSE MISFIRES COULD
OCCUR AFTER AS LITTLE AS 40 ROUNDS BEING FIRED.
6. POC IS @IR. OWEN WASMOEN, AMSMC-QAS-C, DSN 793-7571 OR
COMMERCIAL (309) 782-7571.
7. THIS AIN EXPIRES 30 NO%' 91 UNLESS OTHERWISE RESCINDED OR
SUPERSEDED.
Document Page: First | Prev | Next | All | Image | This Release | Search
Document 13 f:/Week-22/BX001440/24 IN DIV PROCEDURES/maintenance advisory on safety of use messages:0614961651115
Control Fields 17
File Room = jun96_declassified
File Cabinet = Week-22
Box ID = BX001440
Unit = 24TH ID
Parent Organization = XVIII CORPS
Folder Title = 24 IN DIV PROCEDURES
Folder Seq # = 171
Subject = MAINTENANCE ADVISORY ON SAFETY OF USE MESSAGES
Document Seq # = 5
Document Date =
Scan Date = 14-JUN-1996
Queued for Declassification = 01-JAN-1980
Short Term Referral = 01-JAN-1980
Long Term Referral = 01-JAN-1980
Permanent Referral = 01-JAN-1980
Non-Health Related Document = 01-JAN-1980
Declassified = 14-JUN-1996