Document Page: First | Prev | Next | All | Image | This Release | Search
File: aaatf_01.txtSUBJECT: CWU-77/P COVERALL PROTECTIVE CAPABILITIES DEPARTMENT OF THE AIR FORCE HUMAN SYSTEMS DIVISION (AFSC) WRIGHT-PATTERSON AIR FORCE BASE, OHIO 45433-6503 REPLY TO ATTN OF: TAG 01 FEB 1991 SUBJECT: CWU-77/P COVERALL PROTECTIVE CAPABILITIES TO: USCENTAF REAR/BS-DOS 1. THE CWU-77/P COVERALL IS INTENDED TO BE AN INTERIM SOLUTION FOR GROUNDCREW USE DURING OPERATION DESERT STORM AND IS DESIGNED SPECIFICALLY TO REDUCE THERMAL LOAD WHILE STILL AFFORDING ADEQUATE CW PROTECTION. THE CWU-77/P IS A 20% PBI - 80% NOMEX FABRIC WITH LAMINATED CARBON SPHERES SIMILAR TO THE CWU-66/P AIRCREW COVERALL. HOWEVER, THE FABRIC WEAVE OF THE CWU-77/P IS 10% MORE DENSE WITH A WATER REPELLENT COATING ADDED TO INCREASE LIQUID PROTECTION. THIS IS THE SAME COATING THAT IS CURRENTLY USED ON THE GROUNDCREW ENSEMBLE (GCE) TO INCREASE LIQUID PROTECTION. 2. WITH THE ABOVE IN MIND, THE FOLLOWING INFORMATION IS PROVIDED IN RESPONSE TO YOUR INQUIRY ON THE CWU-77/P COVERALL. A. VAPOR PROTECTION: LABORATORY TESTING DEMONSTRATED THAT THE CWU-66/P AND CWU-77/P FABRIC HAS THE CAPABILITY TO PROVIDE 24 HOURS PROTECTION FOR ALL VAPOR CHALLENGES UP TO 10 LAUNDERINGS. B. LIQUID PROTECTION: (1) THE CWU-66/P FABRIC WAS TREATED AGAINST A LIQUID-VAPOR CHALLENGE OF NEAT HD. NEITHER LIQUID OR VAPOR PENETRATION OCCURRED DURING THE 6 HOUR TEST. WHEN TESTED AGAINST THICKENED HD (APPLIED VIA A DROP TOWER WHERE THE DROPLET STRIKES THE FABRIC AT TERMINAL VELOCITY AND THEN IS PRESSED INTO THE FABRIC, LIQUID PENETRATION OCCURRED AFTER 2 HOURS. THERE WAS NO VAPOR PENETRATION PRIOR TO THIS LIQUID PENETRATION. (2) WE HAVE INITIATED LIQUID PROTECTION TESTING ON THE CWU-77/P FABRIC, BOTH NEW AND LAUNDERED. THESE TESTS SHOULD SHOW A SUBSTANTIAL IMPROVEMENT IN LIQUID PROTECTION DUE TO THE TIGHTER WEAVING AND WATER REPELLENT COATING VERSUS THE CWU-66/P. FINAL RESULTS OF THIS TESTING SHOULD BECOME AVAILABLE WITHIN THE NEXT FEW WEEKS. C. DECON PROCEDURES: (1) DECON PROCEDURES FOR THE CWU-77/P SHOULD BE THE SAME AS FOR THE CURRENT GCE (BDO). IF CONTAMINATED WITH VAPOR, AERATE TO ALLOW FOR OFF-GASSING. IF CONTAMINATED WITH LIQUID, DISPOSE OF THE COVERALL. (NOTE: LAUNDERING IS NOT INTENDED TO BE A DECON PROCEDURE.) D. DONNING/DOFFING PROCEDURES: (1) SUGGEST YOU WORK WITH USAFTAWC. OUR SUGGESTIONS INCLUDE DETERMINING IF LIQUID OR VAPOR CONTAMINATION HAS OCCURRED. IF CONTAMINATED WITH LIQUID, THE COVERALL COULD BE CUT TO REMOVE IT FROM THE INDIVIDUAL. IF
Document Page: First | Prev | Next | All | Image | This Release | Search