Document Page: First | Prev | Next | All | Image | This Release | Search

File: aabcv_02.txt
Page: 02
Total Pages: 3


PAGE03 RHIEFKA0794:
AND PRIME POWER PLANT ( RATION, AS WELL AS DISTRIBUTION OF ASSETS
FROM ONE END OF THE BASE TO THE OTHER, REQUIRE 10 542X2 PERSONNEL.
8 ARE ON HAND, ONE KORE IS APPROVED BUT NOT YET ON HAND. REQUIREMENT
6 EA 551XX PERSONNEL/JUSTIFICATION: LARGE SCALE EQUIPMENT OPERATIONS
TO CONSTRUCT MUNITIONS STORAGE AREA EXPANSION, C-130 DISPERSED PARK-
ING AREA AND TAXIWAYS AND DISPERSED FUEL BERMS ARE REQUIRED. ADDI-
TIONAL EQUIPMENT OPERATORS ARE REQUIRED TO KEEP THESE PROJECTS PRO-
GESSING. 25 ARE ON HAND, FOUR ARE ENROUTE AND DUE 18 OCTOBER, THREE
ARE BEING SOURCED BY CENTAF. REQUIREMENT: 44 AIR CONDITIONING UNITS
JUSTIFICATION: 27 ADDITIONAL REQUIREMENTS EXIST IN TENT CITY AND
AROUND THE BASE TO COOL TENTS, GPS, AND ESC SHELTERS FOR TAC AND MAC
MAINTENANCE, MAC/DO, RM, SECURITY POLICE, AND AERIAL PORT. DUE TO
[(b)(1)sec 3.4(b)(5)]
PERCENT BACK UP LEVEL IS REQUIRED (34 MORE A/C UNITS). 314 INSTALLED
17 BACK UP ON HAND, 44 ADDITIONAL REQUIRED. REQUIREMENT: 3 100 KW
GENERATORS/JUSTIFICATION: EXPANDED TAC/MA, AERIAL PORT, AND MAC/MA
AND DO FACILITES TO ALLEVIATE OPERATIONAL RESTRICTIONS REQUIRE
INCREASED ELECTRICAL POWER.  11 EA 100 KW GENERATORS ON HAND.
REQUIREMENT: 1 EA 60 KW GENERATOR/JUSTIFICATION: POWER REQUIRED FOR

PACE04 RHIEFKA0794
TWO GPS FOR RM T0 USE FOR BASE SUPPLY. 15   60 KW GENERATORS ON HAND.
REQUIREMENT: 1 EA ESC COMMON/JUSTIFICATION: REQUIRED HARD SHELTER
FOR ISSUE OF MODERATE QUANTITIES OF WEAPONS AND AMMUNITION BY
SECURITY POLICE AT TENT CITY DURING INCREASED THREATION.  [(b)(1)sec 3.4(b)(5)]

                      21 EA ESC SHELTERS (ALL TYPES) ON HAND. REQUIREMENT:
VEHICLE WRSK/JUSTIFICATION: PARTICULAR PROBLEMS EXIST WITH CIVIL
ENGINEERING SPECIAL PURPOSE EQUIPMENT. [(b)(1)sec 3.4(b)(5)]

                    AIR FILTERS (FOR EARTH MOVING EQUIPMENTLIKE DOZERS,
GRADERS, ESPECIALLY) ARE UNAVAILABLE FOR FREQUENTLY NEEDED REPLACE-
MENT IN THIS HIGH DUST/SAND ENVIRONMENT.   REQUIREMENT: 100 KW AND 60
KW WRSK/JUSTIFICATION: WRSK SUPPLIED IS INCOMPLETE. BELTS ARE STILL
ONLY AVAILABLE THROUGH HOME STATION. REQUIREMENT: HARVEST FALCON
WRSK (VARIOUS TYPES) ? JUSTIFICATION: WRSK RECEIVED IS INCOMPLETE
SHOWER/SHAVE UNIT WRSK LACKS GASKETS AND VALVES. 9-1 KITCHEN WRSK
LACKS WRSK FOR REFER UNITS AND TILT GRILLS. NO WRSK RECEIVED FOR
LATRINE UNITS. TENT ZIPPERS AND FLOORS ARE FAILING WITH NO WRSK
SUPPLIED. REQUIREMENT: PERMANENT SHOWER/LATRINE/SHAVE  FACILITIES/

Document Page: First | Prev | Next | All | Image | This Release | Search