Document Page: First | Prev | Next | All | Image | This Release | Search
File: 110196_aachl_01.txtSUBJECT: WARNER-ROBINS AIR LOGISTIC CENTER INTERIM SAFETY SUPPLEMENT 14P4-15-1SS-7 TO MCU-2/P SERIES GAS MASK UNCLASSIFIED PENTAGON OPERATIONS DIRECTORATE FLASH ZYUW RUVRAAA7858 0112002 Z 112010Z JAN 91 ~ FM WR-ALC ROBINS AFB GA//LV// - TO RUQVAAF/HP ESC KELLY AFB TX//LRC/LGS/LGM// RH1UFAA/USCENTAF//DOS// RHCUAAA/HQ MAC SCOTT AFB 1L//LRC/LGS/LGM// RHDJSAA/HQ AFSC ANDREWS AFB MD//LRC/LGS/LGM// RUCUAAA/HQ SAC OFFUTT AFB NE//LRC/LQS/LGM// RHD1AAA/HQ TAC LANGLEY AFB VA//LRC/LGS/LGM// RHFQAAA/HQ U5AFE RAMSTEIN AB CE//LRC/LGS/LGM// RUVAFLC/HQ AFLC WRIGHT PATTERSON AFB OH//LRS/LGS/LGM// RHCPMXA/HQ AU MAXWELL AFB AL//LRC/LGS/LGM// RHWRATC/HQ ATC RANDOLPH AFB TX//LRC/LGS/LGM// RUHVPAC/HQ PACAF HICKAM AF8 HL//LRC/LGS/LGM// RHCUABA/HQ AFCC SCOTT AFB IL//LRC/LGS/LGM// RHDJGBA/NGB ANDREWS AFB MD//LRC/LOS/LGM// -RHCDAAA/HQ AFSOC HURLBURT FLD FL//LRC/LGS/LGM// ~. RUWTRFA/HQ USAFA COLORADO SPRINGS CO//XPR/LGS/LGR/LGM// ZEN/HQ AFRES ROBINS AFB GA//CSS/LRG/LGX/SAG/DOXR/ LGM// AIG 570// - - A1G 579//BS/SG/DW/DM// - RUEOHUA/NAVSSES PHLLADELPHLA PA CODE 045C// INFO RUVEFFA/AFDPRC LOWRY AFB CO//PR// RUEAHQA/HQ USAF WASHINGTON DC//XOOTM/LEY/LEX// UNCLAS . SUBJ: INTERLM SAFETY SUPPLEMENT L4P4-15-1SS-7 TO MCU-2/P SERIES GAS MASK A. 3-7-B CHANGE THE WORDS COLLAPSES AND COLLAPSED TO DEFLECT AND DEFLECTED. B. AFTER STEP 3-7-F ADD THE FOLLOWING WARNING AND PROCEDURAL STEPS. WARNING: IF DURING THE NEGATIVE PRESSURE CHECK THE MASK RAPIDLY DECOMPRESSES, POSSIBLY ACCOMPANIED BY A POPPING SOUND, REMAIN CALM AND PROCEED AS FOLLOWS: ADD AS 3-7-G - 1. STOP BREATHING (HOLD YOUR BREATH) AND CLOSE YOUR EYES. 2. .WITH ONE HAND HOLD THE FACEPIECE FIRMLY AGAINST THE FACE. 3. PULL THE B0TTOM TAB ON THE BLACK OUTLET VALVE COVER DOWN AND OUT TO EXPOSE THE OUTLET VALVE DISC. 4. DISLODGE OUTLET VALVE DISC FROM VALVE BODY BY LIGHTLY RUBBING THE VALVE DISC 1N A CIRCULAR MOTION. HAVE YOUR BUDDY HELP YOU IF POSSIBLE. 5. CLEAR MASK BY EXHALING. 6. CALMLY REPEAT NEGATIVE PRESSURE CHECK. 7. OPEN EYES AND BREATH NORMALLY. 8. REPLACE OUTLET VALVE COVER. 9. IF DISC OUTLET VALVE WERE TO HAVE COLLAPSED IN A SUSPECTED CHEMICALLY CONTAMINATED AREA, REESTABLISH SEAL AND SEEK MEDICAL ATTENTION AT THE FIRST OPPORTUNITY. C. POINT OF CONTACT [(B)(2)] BT
Document Page: First | Prev | Next | All | Image | This Release | Search