 PAGE 1 MLN= 032 >>> I M N E O I A T E <<<
 DAN=401-07042S OCDSN=MCP036
 TOR = 170048Z AUG 90
 
 ACTION = [BCC]280(2) CP(1)
	[GUN]SSC(2)   CS(1)
 INFO =
 
 TOTAL COPIES = 00003    MDC = 15
 
 OATUZYUW RMDJGAA0622 2290042-UUUU--RHCPMXA RHCPGUN.
 ZNR UU U U U
 O 162351Z AUG 90
 FM NGB ANDREWS AFB MO//DEO//
 TO AIG 7370//CC/DCS/DO/MA/RM/AO/DW/LGS//
 AIG 7319
 MULTIPLE ADDRESSEES
 UNCLAS
 QQQQ
 AIG 7319 TAKE FOR INFO ONLY
 SUBJ: M6A2 HOOD INSPECTION REQUIREMENTS - (MESSAGE 2)
 REF: NGB/DEO MSG, 160151Z AUG 90
 1. THE FOLLOWING INFORMATION IS PROVIDED CONCERNING INSPECTING OF
 M6A2 HOODS:
 A. DUE TO RECENTLY DISCOVERED DISCREPANCIES ON A SIGNIFICANT
 NUMBER OF M6A2 HOODS, ALL ANG UNITS ARE REQUIRED TO INSPECT ALL
 REPEAT ALL M6A2 ASSETS REGARDLESS OF LOT NUMBER. THIS INCLUDES ALL
 HOODS PACKED INSIDE TYPE C MOBILITY BAGS.
 B. DURING THE INSPECTIONS, PARTICULAR ATTENTION SHOULD BE GIVEN TO
 
PAGE 02 RHOJGA406ZZ UNCLAS
 THE AREA OF THE SEAMS.  LOOKING FROM THE INSIDE OF THE HOOD, THE
 SEAM SHOULD BE COVERED WITH A LAYER OF SEALANT. THE PURPOSE OF
 THIS SEALANT IS TO COVER THE HOLES MADE BY THE SEWING NEEDLES
 DURING MANUFACTURE. IF THESE SEAMS ARE NOT COVERED/IF YOU CAN SEE
 BARE STITCHES THEN THE HOOD IS UNSERVICEABLE.
 C. AT THIS TIME, THERE IS NO AUTHORIZED, REPEAT, NO AUTHORIZED
 PROCEDURE FOR ACCOMPLISHING LOCAL REPAIR. ANY UNIT ATTEMPTING
 LOCAL R EPAIR OF SEAMS SHOULD CEASE THOSE EFFORTS IMMEDIATELY. THE
 ENGINEER AT ABERDEEN PROVING GROUND RESPONSIBLE FOR THESE HOODS,
 WILL INVESTIGATE THE POSSIBILITY OF DEVELOPING A LOCAL REPAIR
 

Document Page: First | Prev | Next | All | Image | This Release | Search