File: 120596_aabxc_02.txtIS COLLAPSED ON YOUR FACE, VERIFY SEAL WITH APPLICATOR DIPPED IN N-AMYL ACETATE {BANANA OIL} {NSN 6810-00-123-7047} BY MOVING THE APPLICATOR AROUND THE OUTLET VALVE AREA. D. IF AN AIR LEAK OR BANANA SCENT IS DETECTED. DO THE FOLLOWING: (1) REMOVE AND DISCARD THE OUTLET VALVE. ( 2) CLOSELY INSPECT AND CLEAN AND INSERT A NEW OUTLET VALVE. (3) RETEST AND VALIDATE AS BEFORE {PARA 2C}. (4) IN THE EVENT THAT THE REPLACEMENT VALVE STILL DOES NOT PROVIDE A SEAL. TURN THE MASK IN FOR REPLACEMENT. 3. REQUEST WIDEST DISSEMINATION TO ALL SOLDIERS. CML OPS AND MAINTENANCE PERSONNEL. UNQUOTE 2. HQ SAC/SGAX POC [(b)(2)]