          IS COLLAPSED ON YOUR FACE, VERIFY SEAL WITH APPLICATOR DIPPED IN
          N-AMYL ACETATE {BANANA OIL} {NSN 6810-00-123-7047} BY MOVING THE
          APPLICATOR AROUND THE OUTLET VALVE AREA.

           D. IF AN AIR LEAK OR BANANA SCENT IS DETECTED. DO THE
              FOLLOWING:

                  (1) REMOVE AND DISCARD THE OUTLET VALVE.
         	     ( 2) CLOSELY INSPECT AND CLEAN AND INSERT A NEW OUTLET
          VALVE.
                  (3) RETEST AND VALIDATE AS  BEFORE {PARA 2C}.
  	     (4) IN THE EVENT THAT THE REPLACEMENT VALVE STILL DOES NOT
          PROVIDE A SEAL. TURN THE MASK IN FOR REPLACEMENT.
         3.   REQUEST WIDEST DISSEMINATION TO ALL SOLDIERS. CML OPS AND