File: 120596_aabxc_01.txtFROM: HQ SAC OFFUTT AFB NE TO AIG 9462//SGAX// ZEN EHRLING BERQUIST STRATHOSP AFB NE UNCLASSIFIED SUBJ: CB MASK M17, M24/25 SERIES MASK OUTLET VALVE 1. THE FOLLOWING CDR AMCCOM APG MD/AMSMC-MAR-EP MSG. 24ll00Z DEC 90 IS QUOTED IN PART FOR YOUR INFORMATION: QUOTE 2. AS A RESULT OF THE ENVIRONMENTAL CONDITIONS EXPERIENCED IN SOUTH WEST ASIA. THE FOLLOWING ADDITIONAL ACTIONS ARE REQUIRED TO ENSURE CB MASK READINESS: A. FOLLOW THE PMCS PROCEDURES OUTLINED IN THE APPROPRIATE TMS CLOSELY AS IT PERTAINS TO OUTLET VALVE INSPECTION CLEANING AND SERVICE. {REF TM 4240-279-20&P W/C2 PAGE 2-15 & 2-16 AND TM 4240-280-20&P W/C2 PAGE 2-8} B. USING A COTTON TIPPED APPLICATOR. {NSN 6515-00-303-8250} MOISTENED IN ALCOHOL {NSN 6505-00-655-8366} THOROUGHLY CLEAN THE OUTLET VALVE SURFACES AND VALVE SEAL OF ANY DUST, DIRT, OR SAND C. WITH THE MASK PROPERLY FITTED ON THE FACE. INHALE AND HOLD YOUR BREATH FOR 10-l5 SECONDS. AT THE SAME TIME WHILE THE MASK [(b)(2)]