AFRD-DTO 11 December 1990
DECISION MEMORANDUM FOR CG
SUBJECTI Fielding PI-XMZI Remote Sensing Chemical Agent Alarm
Prototypes (12)
1. (U) This is a Decision Memorandum. There is no suspense
2. +" PURPOSE. To obtain CG approval to field five XM21
Remote Sensing Chemical Agent Alarm prototypes into the AOR.
3. DISCUSSION.
A. AVAILABILITY. Currently 5 XM21s are available for
ARCENT use. A two-man contact team can support training,
maintenance, and employment of these systems. They're willing to
remain in theater as long as necessary to insure successful XmZl
employment. If team or user determine system doesn't function
properly, or provide anticipated benefit, team will remove XMZls
from AOR. Upon notification team needs 3 weeks to arrive in
country.
B. CAPABILITIES. XM21 is a field deployable, passive
infrared sensor/signal processor that remotely detects nerve
(G-Series) and blister agent clouds at line-of-sight distances out
to 5 kms. It soans a 60 degree field of view in seven distinct
segments within one minute. It proposes no health or safety
hazard to operator or adjacent areas. System consists of a
detector, tripod with accessories, transit case, battery cables,
4(HN (24 V) lead-acid batteries, and a NATO adaptor for vehicle
power.
C. EMPLOYMENT. Army employment concept for the XM21
focuses on fixed sites operations (ie port facilities, maintenance
depots, airports, etc) to minimize need for transporting the
operator would need to check XMZI periodically
(ie once every hour). System's central panel will inform operator
of nerve or blister agent alarm and identify which fields of view
are in alarm.
D. MAINTENANCE. XMZls would arrive in theater with
system support package (ie. spare/repair parts). Additionally,
contractors would coordinate maintenance with USMC in-country
maintainers. XM21s require monthly maintenance at DS level to
check internal system alignment. Depot level repair would be at
the contractor's facility in Florida.
E. LIMITATIONS:
1. System is fragile; must be restrained during
transport. Best used at fixed sites.
UNCLASSIFIED
Document Page: First | Prev | Next | All | Image | This Release | Search
Document 1 f:/Week-29/BX000420/HISTORIANS BACKGROUND MATERIAL FILES - G3 NBC MIS 2 OF 4/fielding of xm21 prototypes 11 dec 90:10019616504743
Control Fields 17
File Room = jul96_declassified
File Cabinet = Week-29
Box ID = BX000420
Unit = ARCENT
Parent Organization = CENTCOM
Folder Title = HISTORIANS BACKGROUND MATERIAL FILES - G3 NBC MIS 2 OF 4
Folder Seq # = 3
Subject = FIELDING OF XM21 PROTOTYPES 11 DEC 90
Document Seq # = 107
Document Date =
Scan Date =
Queued for Declassification = 01-JAN-1980
Short Term Referral = 01-JAN-1980
Long Term Referral = 01-JAN-1980
Permanent Referral = 01-JAN-1980
Non-Health Related Document = 01-JAN-1980
Declassified = 01-OCT-1996