Document Page: First | Prev | Next | All | Image | This Release | Search
File: 120396_mar96_decls4_0001.txt
Subject: CONTINGENCY PLAN FOR PIPELINE PARALLEL TO MSR DODGE
Unit: XVIII CORPS
Parent Organization: ARCENT
Box ID: BX000020
Folder Title: DUTY LOG G3 REAR PLANNING DOCUMENTS
Document Number: 11
Folder SEQ #: 3
f . @
0
MEMORANDUM
From: 116 SC RAO Area Damage Control
To: 2Sl SC RAO
116 SC RAO FORWARD
Subi: Contingency Plan for Pipeline Parallel to MSR Dodge
1. The pipeline is not in continuous use, but is full and pressurized
psi. It belongs to ARAMCO and they make any necessary repairs and must
notified to turn it off. 5 U.S.C. 552 (B)(6)
2. Any breaks in the pipeline Bhould be reported I
Whiskey area it would be
ARAMCO can be notified also by notifying the 416th Engineers at
9-7805-612/613/614/61S.
3. In addition to the phone notification, a spot report should be Bent
through the G-3 channels. The information in this report will go outs
army channels, BO it MUBT include the following:
a. There is a number on the pipe every kilometer, the nearest n
should be included in the report.
b. Now the pipe was ruptured is needed so that the correct repair
equipment is ordered.
This spot report should be Bent to the attention of the Corps ACE who
determine if Corps firefighting assets are available.
4.(U)@Bases in close proximity to the pipe should plan for berms or di
that would keep the results of a spill out of the compound. The pressl
oil also gives off toxic fumes (14ydrogen Sulfide) which smells like rot
eggs. Field protective masks should be worn in proximity to the rupture.
Field Protective masks will provide protection until the BMell of rottei
becomes apparent in the mask, then the filters MUST be changed.
S. Forward questions to this Office, POC CPT LACY.
Paul D. Lacy
CPT EN
CC: ARCENT ENOR (MAJ Bush)
XVIII AEN PS G-5
*CVIII ABN CPS G-3
UNCLASSIFIED DECLASSIFIED ON 29 Mar
1996 PER SECARMY
(DAMH) UP SEC 3.4 EO
12958
Document Page: First | Prev | Next | All | Image | This Release | Search
Document 2 f:/Week-10/BX000020/DUTY LOG G3 REAR PLANNING DOCUMENTS/contingency plan for pipeline parallel to msr do:1108961513575
Control Fields 17
File Room = mar96_declassified
File Cabinet = Week-10
Box ID = BX000020
Unit = XVIII CORPS
Parent Organization = ARCENT
Folder Title = DUTY LOG G3 REAR PLANNING DOCUMENTS
Folder Seq # = 3
Subject = CONTINGENCY PLAN FOR PIPELINE PARALLEL TO MSR DO
Document Seq # = 11
Document Date =
Scan Date =
Queued for Declassification = 01-JAN-1980
Short Term Referral = 01-JAN-1980
Long Term Referral = 01-JAN-1980
Permanent Referral = 01-JAN-1980
Non-Health Related Document = 01-JAN-1980
Declassified = 08-NOV-1996