Subject = M8A1 CHEMICAL AGENT ALARM
Box ID = BX001610
Folder Title = LESSONS LEARNED
Unit = 101ST ID
Parent Org = XVIII CORPS
CHEMICAL
LESSONS LEART)ED
LIPERAI'ION DF-SER'T S141ELD
ISI,iiJE: MBAI Chemical f)qent Alarm.
@,i@UbLEMS ENCUUNI'ERED,. The MBAI has been noted to qive off false
alarms. It only detects one chemical a(3ent (nerve). There are also
problems with maintenance and handling of detL-cte3r cells.
ulbLUSSION: Overall performance of the MBAI Chemical Alarm is
t.itizati sf -ictory.
Many false alarms Occur while operating the alarm. False alarms
are caused by e>,tiaL(st ft-(mes, dust, petroleum products and low
battery povier.
- the MSAI has a radioactive Source which requires special hanll-
linq. Detector cells are not easily replaced and the wait time for
replacement is L-Ycessive.
- the Liltra-fine talc-lile sand particles experienced in the area
of oper,@itionc- tended to have an %dverse effect on the MBA Alarm
plirclir)q operations.
- Ihe MBAI takes -A special battery - a 24 /olt BAT,517/U - in which
no other- equipment can use. The battery has a life of less than 5
days or 10-12 hour missions.
- ]he MBAI is very limited in detection - it only detects nerve
aqent.
El'- LCJMMENI)@-I f I O@l: Replace the MBAI with the new agent detector ICAD
(individual E;heinical Aaent Detector). Also. replace with the XM21
Nefnote C@iL-ii)ic-ztl AqL-nt Alarm.
BILI-Y R. DHEEL, SFC, DIV CHEM