,PNGL@SSIFIED
@ I
PRIORITY ZYUW RUFRSGG1192 0311626
P 310909Z JAN 01
Ft'i COMUSNA\?LDGSUPFOR//'N9i'/
TO USCINCCENT CNO WASHINGTON DC//0932//
BUMED WASHINGTON DC//27//
INFO COMUSNAVCENT
//ND6000//
OPER/DESERT STORM//
MSGID/SYS.RRM/COMUSNAVLOGSUPFOR/-/JAN//
AMPN/SUBJ: HIGH FALSE POSITIVE RATE OF ANTHRAX SMART TESTS
REF/A/SYS.RRM/USCINCENT/18081IZJAN91//
REF/B/TEL/COMUSNAVLOGSUPFOR/26JAN91//
NARR/REF A OUTLINED DISTRIBUTION OF SUBJ KITS. REF B WAS TELCON CDR
ESCAMILLA NLSF N9/COL BALES CINCCENT/CCSG/26JAN9] WRT HIGH FALSE
POSITIVE @ATE//
RMKS/1. ) REF A ANNOUNCED AVAILABILITY AND DISTRIBUTION OF SMART
TEST KITS FOR USE BY MEDICAL UNITS TO DETECT ANTHRAX ANTIGEN IN
CLINICAL SPECIMENS. PER REF B ORIG NAVY FORWARD LAB (NFL) REPORTED
SUBJECT PROBLEM IN KIT LOTS 100, 101, AND 104. OTHER LOT NUMBERS
HAV @ OT BEEN EVALUATED BY NFL.
2. IN VIEW OF THE SERIOUSNESS AND POSSIBLE ADVERSE CONSEQUENCES
OF THIS PREVIOUSLY UNRECOGNIZED PROBLEM ORIG HAS TAKEN THE OPTION NOT
TO DISTRIBUTE SUBJECT TEST KITS. REQUEST OFFICIAL DECISION AND FINAL
DISPOSITION OF SUBJECT TEST KITS AS SOON AS POSSIBLE.
3. 'V IN VIEW OF THE PROBLEM DOCUMENTED WITH ANTHRAX ANTIGEN
DETECTIONS KITS, REQUEST THAT OTHER SMART FORMAT TESTS FIELDED OR
SOON TO BE FIELDED FOR DETECTION OF CLOSTRIDIUM BOTULISM TOXIN,
PLAGUE, AND ANTHRAX SPORES BE EXAMINED AT U.S. ARMY MEDICAL RESEARCH
CTIOUS DISEASE USAMRIID) OR OTHER COMPETENT
LABORATORY AND THAT PERFORMANCE CHARACTERISTICS OF THESE ADDITIONAL
7ESTS BE ASSURED AS SOON AS POSSIBLE.
(LI) COtiL]SNAVLOGSUPFOP. POC: LCDR B!G@@S,
5. (U) RELEASED BY CAPT T. COOK//
OPCL/OADR// BT 5 U.S.C. 552 (b)(6)
DECLASSIFIED
ON: 24 OCT 96
BY: DON GWDP IAW OPNAVINST 5513. SERIES
CNO WASH DC ADV 43
ACTION 093(l) (U,F)
N F 0 00 (1) CNO GRID(L) 09(l) 09B(l) 095(l) 08(1' 80(i)
0 1 (1) 02 (1) 03 (1) 07EG (1) 30 (1) 35 (1) 37 (1) 39 (1)
04(l) 40 (1) 41 (1) 42(i) 44(l) 05(l) 50(i) 51 (1)
0 55 (1) O@l 60 (1) AA (1) 61 (1) 64 (1) 932 (1) 76 (1)
07 (1) 70 (1) 71 (1) 75(l) 73(l) DS(l) 74(l) NRC(L)
NCC(L) 922Y (1) SC (1)
MCN=91031/26307 TDR=91031/1726Z TAD=gIC31/1745Z '-DSN=M4D414
PAGE I OF I
SEERET 3109092 JAN 91
UNCLASSIFIED
Document Page: First | Prev | Next | All | Image | This Release | Search
Document 1 f:/Week-41/BX300098/FOLDER MESSAGE CHRONOLOGICAL FILES 26 JAN 12 FEB 91 6 OF 18/high false positive rate of anthrax smart tests:11049611392721
Control Fields 17
File Room = oct96_declassified
File Cabinet = Week-41
Box ID = BX300098
Unit = US NAVY
Parent Organization = US NAVY
Folder Title = FOLDER MESSAGE CHRONOLOGICAL FILES 26 JAN 12 FEB 91 6 OF 18
Folder Seq # = 6
Subject = HIGH FALSE POSITIVE RATE OF ANTHRAX SMART TESTS
Document Seq # = 37
Document Date =
Scan Date =
Queued for Declassification = 01-JAN-1980
Short Term Referral = 01-JAN-1980
Long Term Referral = 01-JAN-1980
Permanent Referral = 01-JAN-1980
Non-Health Related Document = 01-JAN-1980
Declassified = 04-NOV-1996