Subject = GENERAL FIELD SANITATION SURVEY 20 FEB 91
Box ID = BX000284
Folder Title = GENERAL FIELD SANITATION SURVEY 12TH EVAC HOSPITAL
Unit = VII CORPS
Parent Org = ARCENT
DECLASSIFIED
ON: 18 MAR 98
BY: SEC ARMY (DAMH) UNDER SEC 3.4 EO 12958
DEPARTMENT OF THE ARMY
14TH PREVENTIVE MEDICINE UNIT
APO NEW YORK 09698
20 February 1991
MEMORANDUM TO: Commander, Task Force Evac, 332d Medical Brigade
THRU: Commander, 14th Preventive Medicine Unit.
1. DATE SURVEY: 5 February 1991. ...
2. TYPE OF SURVEY: General Field Sanitation Survey.
3. UNIT: 148th Evac Hospital.
4. DISCREPANCIES:
LATRINES AND SANITATION
a. All types of wastes are being burned in one common pit.
b. No urinal tubes are present near male latrines.
C. Latrine cans are not being burned out correctly. Wastes are being
dumped into a burn pit, where burning is not complete.
d. No pesticides are being used to control flies around latrines.
e. Handwashing facilities are too low. Soakage pits are too small and
contain standing water.
f. Trash is not being stored in bags properly.
MESS FACILITY
a. Storage racks in dry storage unit are too close to ground.
b. No grease trap or soakage pit in place.
C. Refrigeration unit relay not working properly. Temperature is being
maintained manually.
d. Produce is being stored directly on refrigerator floor.
S. RECOMMENDATIONS:
-LATRINES AND SANITATION
a. Wastes should be segregated into hazardous and non-hazardous pits.
b. Construct 3 urinal tubes in the vicinity of each male latrine.
C. Latrine cans should be burned out individually to a fine ash by a
burning a mixture of I part mogas to 3 part diesel.
d. Wed flybait or a pesticide with ample residual killing power in
latrines.
e. Raise handwashing facilities and enlarge soakage pits. Place rocks
in soakage pits to prevent standing water.
f. All bagged trash should be stored in a specified area. Bagged trash
should be hauled to a burn pit on a more regular basis.
MESS FACILITY
a. Raise storage racks in dry storage unit to comply with minimum
specifications listed in TS Med 530.
b. Strain mess kit laundry waste into a soakage pit in accordance with
FM 21-10 or FC-8-6.
C. Refrigerator relay should be repaired to eliminate need for manual
temperature regulation. Unit was advised of refrigeration repair
unit at Al Qusaymah.
d. Elevate produce on boards to provide adequate distance from floor.
Document Page: First | Prev | Next | All | Image | This Release | Search